Get the app in the App Store and on Google Play!

PHENYL MERCAPTAN

6.1 - Poison Inhalation Hazard 3 - Flammable liquid
Add to MyChemicals

The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number
  • 108-98-5   (PHENYL MERCAPTAN)
DOT Hazard Label USCG CHRIS Code
  • Poison Inhalation Hazard
  • Flammable Liquid
NIOSH Pocket Guide International Chem Safety Card
Benzenethiolexternal_link
NFPA 704
data unavailable
General Description
A clear liquid with a repulsive odor. Boiling point 168.3°C. Insoluble in water and denser than water. Very toxic by ingestion, skin absorption, and by inhalation. Used as a chemical intermediate and in mosquito control.

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
  • Air-Reactive
Air & Water Reactions
Flammable. Oxidizes upon exposure to air, especially when dissolved in alcoholic ammonia, to form diphenyl disulfide, C6H5SSC6H5 [Merck 11th ed. 1989]. Is supplied under an atmosphere of nitrogen. Insoluble in water.
Fire Hazard
When heated to decomposition or on contact with acids, it emits toxic fumes of sulfur oxides. May be ignited by heat, sparks or flames. Container may explode in heat of fire. Vapor explosion and poison hazard indoors, outdoors or in sewers. Unstable, oxidizes in air. Avoid contact with acids. (EPA, 1998)
Health Hazard
Marked potential for causing eye changes. May cause death (EPA, 1998)
Reactivity Profile
PHENYL MERCAPTAN reacts with acids to generate toxic fumes of oxides of sulfur. [Lewis, 3rd ed., 1993, p. 1021]. Reacts exothermically with strong oxidizing agents.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

No information available.

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 131 [Flammable Liquids - Toxic]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.

SPILL: See ERG Table 1 - Initial Isolation and Protective Action Distances on the UN/NA 2337 datasheet.

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Firefighting
Keep unnecessary people away; isolate hazard area and deny entry. Stay upwind; keep out of low areas. Ventilate closed spaces before entering them. Wear positive pressure breathing apparatus and special protective clothing.

Small fires: dry chemical, carbon dioxide, water spray or foam. Large fires: water spray, fog or foam. Move container from fire area if you can do so without risk. Spray cooling water on containers that are exposed to flames until well after fire is out. Fight fire from maximum distance. Dike fire control water for later disposal; do not scatter the material. (EPA, 1998)
Non-Fire Response
Excerpt from ERG Guide 131 [Flammable Liquids - Toxic]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors.

SMALL SPILL: Absorb with earth, sand or other non-combustible material and transfer to containers for later disposal. Use clean, non-sparking tools to collect absorbed material.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2024)
Protective Clothing
Excerpt from NIOSH Pocket Guide for Benzenethiolexternal link:

Skin: PREVENT SKIN CONTACT - Wear appropriate personal protective clothing to prevent skin contact.

Eyes: PREVENT EYE CONTACT - Wear appropriate eye protection to prevent eye contact.

Wash skin: WHEN CONTAMINATED - The worker should immediately wash the skin when it becomes contaminated.

Remove: WHEN WET OR CONTAMINATED - Work clothing that becomes wet or significantly contaminated should be removed and replaced.

Change: No recommendation is made specifying the need for the worker to change clothing after the workshift.

Provide:
• EYEWASH - Eyewash fountains should be provided in areas where there is any possibility that workers could be exposed to the substances; this is irrespective of the recommendation involving the wearing of eye protection.
• QUICK DRENCH - Facilities for quickly drenching the body should be provided within the immediate work area for emergency use where there is a possibility of exposure. [Note: It is intended that these facilities provide a sufficient quantity or flow of water to quickly remove the substance from any body areas likely to be exposed. The actual determination of what constitutes an adequate quick drench facility depends on the specific circumstances. In certain instances, a deluge shower should be readily available, whereas in others, the availability of water from a sink or hose could be considered adequate.] (NIOSH, 2024)
DuPont Tychem® Suit Fabrics
Tychem® Fabric Legend
QS = Tychem 2000 SFR
QC = Tychem 2000
SL = Tychem 4000
C3 = Tychem 5000
TF = Tychem 6000
TP = Tychem 6000 FR
RC = Tychem RESPONDER® CSM
TK = Tychem 10000
RF = Tychem 10000 FR
Testing Details
The fabric permeation data was generated for DuPont by a third party laboratory. Permeation data for industrial chemicals is obtained per ASTM F739. Normalized breakthrough times (the time at which the permeation rate exceeds 0.1 μg/cm2/min) are reported in minutes. All chemicals have been tested between approximately 20°C and 27°C unless otherwise stated. All chemicals have been tested at a concentration of greater than 95% unless otherwise stated.
Chemical warfare agents (Lewisite, Sarin, Soman, Sulfur Mustard, Tabun and VX Nerve Agent) have been tested at 22°C and 50% relative humidity per military standard MIL-STD-282. "Breakthrough time" for chemical warfare agents is defined as the time when the cumulative mass which permeated through the fabric exceeds the limit in MIL-STD-282 [either 1.25 or 4.0 μg/cm2].
A Caution from DuPont
This information is based upon technical data that DuPont believes to be reliable on the date issued. It is subject to revision as additional knowledge and experience are gained. The information reflects laboratory performance of fabrics, not complete garments, under controlled conditions. It is intended for informational use by persons having technical skill for evaluation under their specific end-use conditions, at their own discretion and risk. It is the user's responsibility to determine the level of toxicity and the proper personal protective equipment needed. Anyone intending to use this information should first verify that the garment selected is suitable for the intended use. In many cases, seams and closures have shorter breakthrough times and higher permeation rates than the fabric. If fabric becomes torn,abraded or punctured, or if seams or closures fail, or if attached gloves, visors, etc. are damaged, end user should discontinue use of garment to avoid potential exposure to chemical. Since conditions of use are outside our control, DuPont makes no warranties, express or implied, including, without limitation, no warranties of merchantability or fitness for a particular use and assume no liability in connection with any use of this information. This information is not intended as a license to operate under or a recommendation to infringe any patent, trademark or technical information of DuPont or others covering any material or its use.
Normalized Breakthrough Times (in Minutes)
Chemical CAS Number State QS QC SL C3 TF TP RC TK RF
Benzene thiol 108-98-5 Liquid >480 >480 >480
Phenyl mercaptan 108-98-5 Liquid >480 >480 >480
> indicates greater than.

Special Warning from DuPont: Tychem® and Tyvek® fabrics should not be used around heat, flames, sparks or in potentially flammable or explosive environments. Only...

...Tychem® ThermoPro, Tychem® Reflector® and Tychem® TK styles 600T/601T (with aluminized outer suit) garments are designed and tested to help reduce burn injury during escape from a flash fire. Users of Tychem® ThermoPro, Tychem® Reflector® and Tychem® TK styles 600T/601T (with aluminized outer suit) garments should not knowingly enter an explosive environment. Tychem® garments with attached socks must be worn inside protective outer footwear and are not suitable as outer footwear. These attached socks do not have adequate durability or slip resistance to be worn as the outer foot covering.

(DuPont, 2024)

First Aid
Signs and Symptoms of Acute Thiophenol Exposure: Acute exposure to thiophenol may result in cough, difficulty in breathing, irritation of the lungs, and pneumonia. Nausea, vomiting, and diarrhea are often seen. Contact with thiophenol may result in irritation and redness, pain, inflammation, and severe burns to the skin, eyes, and mucous membranes.

Emergency Life-Support Procedures: Acute exposure to thiophenol may require decontamination and life support for the victims. Emergency personnel should wear protective clothing appropriate to the type and degree of contamination. Air-purifying or supplied-air respiratory equipment should also be worn, as necessary. Rescue vehicles should carry supplies such as plastic sheeting and disposable plastic bags to assist in preventing spread of contamination.

Inhalation Exposure:
1. Move victims to fresh air. Emergency personnel should avoid self-exposure to thiophenol.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
3. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
4. Transport to a health care facility.

Dermal/Eye Exposure:
1. Remove victims from exposure. Emergency personnel should avoid self- exposure to thiophenol.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
3. Remove contaminated clothing as soon as possible.
4. If eye exposure has occurred, eyes must be flushed with lukewarm water for at least 15 minutes.
5. THOROUGHLY wash exposed skin areas with water for at least 15 minutes.
6. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
7. Transport to a health care facility.

Ingestion Exposure:
1. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
2. DO NOT induce vomiting.
3. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
4. Activated charcoal is of no value.
5. Give the victims water or milk: children up to 1 year old, 125 mL (4 oz or 1/2 cup); children 1 to 12 years old, 200 mL (6 oz or 3/4 cup); adults, 250 mL (8 oz or 1 cup). Water or milk should be given only if victims are conscious and alert.
6. Transport to a health care facility. (EPA, 1998)

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.

Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula:
  • C6H6S
Flash Point: 127°F (USCG, 1999)
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: 5.4°F (EPA, 1998)
Vapor Pressure: 1 mmHg at 65.48°F (EPA, 1998)
Vapor Density (Relative to Air): data unavailable
Specific Gravity: 1.0728 at 77°F (EPA, 1998) - Denser than water; will sink
Boiling Point: 334.9°F at 760 mmHg (EPA, 1998)
Molecular Weight: 110.17 (EPA, 1998)
Water Solubility: 0.08 % at 77°F (NIOSH, 2024)
Ionization Energy/Potential: 8.33 eV (NIOSH, 2024)
IDLH: data unavailable

AEGLs (Acute Exposure Guideline Levels)

Final AEGLs for Phenyl mercaptan (108-98-5)
Exposure Period AEGL-1 AEGL-2 AEGL-3
10 minutes NR 1 ppm 3 ppm
30 minutes NR 0.7 ppm 2.1 ppm
60 minutes NR 0.53 ppm 1.6 ppm
4 hours NR 0.33 ppm 1 ppm
8 hours NR 0.17 ppm 0.52 ppm
NR = Not recommended due to insufficient data
(NAC/NRC, 2024)

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Benzenethiol; (Thiophenol; Phenyl mercaptan) (108-98-5) 0.3 ppm 0.53 ppm 1.6 ppm
(DOE, 2024)

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
Benzenethiol 108-98-5 500 pounds 100 pounds 100 pounds P014
Thiophenol 108-98-5 500 pounds 100 pounds 100 pounds P014

(EPA List of Lists, 2024)

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

This section provides a listing of alternate names for this chemical, including trade names and synonyms.
  • BENZENE, MERCAPTO-
  • BENZENETHIOL
  • MERCAPTOBENZENE
  • PHENOL, THIO-
  • PHENYL MERCAPTAN
  • PHENYLTHIOL
  • THIOPHENOL

Contact Us | Website Satisfaction Surveyexternal_link

Version 3.1.0 rev 1