PROPYLENEIMINE, STABILIZED

3 - Flammable liquid 6.1 - Poison
Add to MyChemicals

The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number
  • 75-55-8   (PROPYLENEIMINE)
DOT Hazard Label USCG CHRIS Code
  • Flammable Liquid
  • Poison
NIOSH Pocket Guide International Chem Safety Card
Propylene imineexternal_link
NFPA 704
data unavailable
General Description
A clear colorless liquid with an ammonia-like odor. Flash point 25°F. Toxic by ingestion, inhalation and through skin absorption. Less dense than water. Vapors are heavier than air. Produces toxic oxides of nitrogen during combustion. Under prolonged exposure to fire or heat the containers may rupture violently and rocket. Used as an organic intermediate.

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
  • Highly Flammable
  • Polymerizable
Air & Water Reactions
Highly flammable. Soluble in water. Reacts slowly and non hazardously with water to form propanolamine or methylethanolamine.
Fire Hazard
Chemical is extremely flammable; vapors are heavier than air. Toxic oxides of nitrogen are produced during combustion. Avoid acids, strong oxidizers. Thermally unstable. Hazardous polymerization may occur. Contact with acid promotes violent polymerization. (EPA, 1998)
Health Hazard
Toxic after acute exposure. Can severely irritate eyes, skin, and lungs. (EPA, 1998)
Reactivity Profile
PROPYLENEIMINE is subject to violent polymerization on contact with an acid. (The inhibitor is intended to prevent polymerization). Incompatible with isocyanates, halogenated organics, peroxides, phenols (acidic), epoxides, anhydrides, and acid halides. Flammable gaseous hydrogen is generated in combination with strong reducing agents, such as hydrides.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

Use caution: Liquids with this reactive group classification have been known to react with the absorbents listed below. More info about absorbents, including situations to watch out for...

  • Mineral-Based & Clay-Based Absorbents
  • Dirt/Earth

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 131 Polymerizable warning [Flammable Liquids - Toxic; polymerization hazard]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.

SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Firefighting
If material is on fire, do not extinguish fire unless flow can be stopped. Use water in flooding quantities as a "fog" and use to cool all affected containers. Keep material out of water sources and sewers. Build dikes to contain flow as necessary. Isolate for 1/2 mile in all directions if tank car or truck is involved in fire.

If material is on fire, use foam, carbon dioxide, or dry chemical. (EPA, 1998)
Non-Fire Response
Excerpt from ERG Guide 131 Polymerizable warning [Flammable Liquids - Toxic; polymerization hazard]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors.

SMALL SPILL: Absorb with earth, sand or other non-combustible material and transfer to containers for later disposal. Use clean, non-sparking tools to collect absorbed material.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2024)
Protective Clothing
Excerpt from NIOSH Pocket Guide for Propylene imineexternal link:

Skin: PREVENT SKIN CONTACT - Wear appropriate personal protective clothing to prevent skin contact.

Eyes: PREVENT EYE CONTACT - Wear appropriate eye protection to prevent eye contact.

Wash skin: WHEN CONTAMINATED - The worker should immediately wash the skin when it becomes contaminated.

Remove: WHEN WET (FLAMMABLE) - Work clothing that becomes wet should be immediately removed due to its flammability hazard (i.e., for liquids with a flash point <100°F).

Change: No recommendation is made specifying the need for the worker to change clothing after the workshift.

Provide:
• EYEWASH - Eyewash fountains should be provided in areas where there is any possibility that workers could be exposed to the substances; this is irrespective of the recommendation involving the wearing of eye protection.
• QUICK DRENCH - Facilities for quickly drenching the body should be provided within the immediate work area for emergency use where there is a possibility of exposure. [Note: It is intended that these facilities provide a sufficient quantity or flow of water to quickly remove the substance from any body areas likely to be exposed. The actual determination of what constitutes an adequate quick drench facility depends on the specific circumstances. In certain instances, a deluge shower should be readily available, whereas in others, the availability of water from a sink or hose could be considered adequate.] (NIOSH, 2024)
DuPont Tychem® Suit Fabrics
Tychem® Fabric Legend
QS = Tychem 2000 SFR
QC = Tychem 2000
SL = Tychem 4000
C3 = Tychem 5000
TF = Tychem 6000
TP = Tychem 6000 FR
RC = Tychem RESPONDER® CSM
TK = Tychem 10000
RF = Tychem 10000 FR
Testing Details
The fabric permeation data was generated for DuPont by a third party laboratory. Permeation data for industrial chemicals is obtained per ASTM F739. Normalized breakthrough times (the time at which the permeation rate exceeds 0.1 μg/cm2/min) are reported in minutes. All chemicals have been tested between approximately 20°C and 27°C unless otherwise stated. All chemicals have been tested at a concentration of greater than 95% unless otherwise stated.
Chemical warfare agents (Lewisite, Sarin, Soman, Sulfur Mustard, Tabun and VX Nerve Agent) have been tested at 22°C and 50% relative humidity per military standard MIL-STD-282. "Breakthrough time" for chemical warfare agents is defined as the time when the cumulative mass which permeated through the fabric exceeds the limit in MIL-STD-282 [either 1.25 or 4.0 μg/cm2].
A Caution from DuPont
This information is based upon technical data that DuPont believes to be reliable on the date issued. It is subject to revision as additional knowledge and experience are gained. The information reflects laboratory performance of fabrics, not complete garments, under controlled conditions. It is intended for informational use by persons having technical skill for evaluation under their specific end-use conditions, at their own discretion and risk. It is the user's responsibility to determine the level of toxicity and the proper personal protective equipment needed. Anyone intending to use this information should first verify that the garment selected is suitable for the intended use. In many cases, seams and closures have shorter breakthrough times and higher permeation rates than the fabric. If fabric becomes torn,abraded or punctured, or if seams or closures fail, or if attached gloves, visors, etc. are damaged, end user should discontinue use of garment to avoid potential exposure to chemical. Since conditions of use are outside our control, DuPont makes no warranties, express or implied, including, without limitation, no warranties of merchantability or fitness for a particular use and assume no liability in connection with any use of this information. This information is not intended as a license to operate under or a recommendation to infringe any patent, trademark or technical information of DuPont or others covering any material or its use.
Normalized Breakthrough Times (in Minutes)
Chemical CAS Number State QS QC SL C3 TF TP RC TK RF
Propylene imine (90%) 75-55-8 Liquid 150 150 150

Special Warning from DuPont: Tychem® and Tyvek® fabrics should not be used around heat, flames, sparks or in potentially flammable or explosive environments. Only...

...Tychem® ThermoPro, Tychem® Reflector® and Tychem® TK styles 600T/601T (with aluminized outer suit) garments are designed and tested to help reduce burn injury during escape from a flash fire. Users of Tychem® ThermoPro, Tychem® Reflector® and Tychem® TK styles 600T/601T (with aluminized outer suit) garments should not knowingly enter an explosive environment. Tychem® garments with attached socks must be worn inside protective outer footwear and are not suitable as outer footwear. These attached socks do not have adequate durability or slip resistance to be worn as the outer foot covering.

(DuPont, 2024)

First Aid
Warning: Propyleneimine can severely irritate eyes, skin, and lungs. Direct eye contact has caused corneal damage. Suspected of having carcinogenic potential in humans. Caution is advised.

Signs and Symptoms of Propyleneimine Exposure: Signs and symptoms of acute exposure to propyleneimine may include irritation, inflammation, and blistering of the skin, eyes, nose, and upper respiratory tract; shortness of breath, increased nasal and laryngeal secretions. Itching, nausea, and periodic vomiting, headache (pain in the temple), dizziness may also be noted. CNS effects may occur.

Emergency Life-Support Procedures: Acute exposure to propyleneimine may require decontamination and life support for the victims. Emergency personnel should wear protective clothing appropriate to the type and degree of contamination. Air-purifying or supplied-air respiratory equipment should also be worn, as necessary. Rescue vehicles should carry supplies such as plastic sheeting and disposable plastic bags to assist in preventing spread of contamination.

Inhalation Exposure:
1. Move victims to fresh air. Emergency personnel should avoid self-exposure to propyleneimine.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer 100% humidified oxygen or other respiratory support.
3. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
4. Rush to a health care facility.

Dermal/Eye Exposure:
1. Remove victims from exposure. Emergency personnel should avoid self-exposure to propyleneimine.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
3. Remove contaminated clothing as soon as possible.
4. If eye exposure has occurred, eyes must be flushed with lukewarm water for at least 15 minutes.
5. Wash exposed skin areas three times with soap and water.
6. Obtain authorization and/or further instructions from the local hospital for performance of other invasive procedures.
7. Rush to a health care facility.

Ingestion Exposure:
1. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer 100% humidified oxygen or other respiratory support.
2. Obtain authorization and/or further instructions from the local hospital for performance of other invasive procedures.
3. DO NOT induce vomiting or attempt to neutralize.
4. Activated charcoal may be administered if victims are conscious and alert. Use 15 to 30 g (1/2 to 1 oz) for children, 50 to 100 g (1-3/4 to 3-1/2 oz) for adults, with 125 to 250 mL (1/2 to 1 cup) of water.
5. Promote excretion by administering a saline cathartic or sorbitol to conscious and alert victims. Children require 15 to 30 g (1/2 to 1 oz) of cathartic; 50 to 100 g (1-3/4 to 3-1/2 oz) is recommended for adults.
6. Rush to a health care facility. (EPA, 1998)

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.

Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula:
  • C3H7N
Flash Point: 25°F (EPA, 1998)
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: -85°F (EPA, 1998)
Vapor Pressure: 112 mmHg at 68°F (EPA, 1998)
Vapor Density (Relative to Air): 2 (EPA, 1998) - Heavier than air; will sink
Specific Gravity: 0.8039 to 0.807 at 77 °F (EPA, 1998)
Boiling Point: 151 to 153°F at 760 mmHg (EPA, 1998)
Molecular Weight: 57.11 (EPA, 1998)
Water Solubility: greater than or equal to 100 mg/mL at 66°F (NTP, 1992)
Ionization Energy/Potential: 9.00 eV (NIOSH, 2024)
IDLH: 100 ppm ; A potential occupational carcinogen. (NIOSH, 2024)

AEGLs (Acute Exposure Guideline Levels)

Final AEGLs for Propyleneimine (75-55-8)
Exposure Period AEGL-1 AEGL-2 AEGL-3
10 minutes NR 83 ppm 170 ppm
30 minutes NR 25 ppm 50 ppm
60 minutes NR 12 ppm 23 ppm
4 hours NR 2.5 ppm 5.1 ppm
8 hours NR 1.2 ppm 2.4 ppm
NR = Not recommended due to insufficient data
(NAC/NRC, 2024)

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Propyleneimine, 1,2- (75-55-8) 0.4 ppm 12 ppm 23 ppm
(DOE, 2024)

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
Aziridine, 2-methyl 75-55-8 10000 pounds 1 pound 1 pound X P067 10000 pounds
Propyleneimine 75-55-8 10000 pounds 1 pound 1 pound 313 P067 10000 pounds

(EPA List of Lists, 2024)

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

RELEASE THEFT SABOTAGE
Chemical of Interest CAS Number Min Conc STQ Security
Issue
Min Conc STQ Security
Issue
Min Conc STQ Security
Issue
Propyleneimine; [Aziridine, 2-methyl-] 75-55-8 1.00 % 10000 pounds toxic

(CISA, 2007)

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

This section provides a listing of alternate names for this chemical, including trade names and synonyms.
  • AZIRIDINE, 2-METHYL
  • AZIRIDINE, 2-METHYL-
  • DL-2-METHYLAZIRIDINE
  • 2-METHYLAZACYCLOPROPANE
  • 2-METHYLAZIRIDINE
  • 2-METHYLETHYLENEIMINE
  • METHYLETHYLENIMINE
  • 2-METHYLETHYLENIMINE
  • PROPYLENE IMINE
  • PROPYLENE IMINE (STABILIZED)
  • PROPYLENE IMINE, STABILIZED
  • PROPYLENEIMINE
  • PROPYLENEIMINE, STABILIZED
  • PROPYLENEIMINE, [STABILIZED]
  • 1,2-PROPYLENEIMINE
  • PROPYLENIMINE
  • 1,2-PROPYLENIMINE