BARIUM PERMANGANATE

5.1 - Oxidizer 6.1 - Poison
Add to MyChemicals

The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number
  • 7787-36-2
DOT Hazard Label USCG CHRIS Code
  • Oxidizer
  • Poison
NIOSH Pocket Guide International Chem Safety Card
none none
NFPA 704
data unavailable
General Description
A purplish colored crystalline solid. Noncombustible, but accelerates burning of combustible material. Finely divided combustible materials may be explosive. May spontaneously ignite on contact with combustible liquids. Contact with sulfuric acid may result in fires or explosions. Used as a disinfectant and to make other permanganates.

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
  • Strong Oxidizing Agent
Air & Water Reactions
Soluble in water.
Fire Hazard
Behavior in Fire: Can increase the intensity of fire. (USCG, 1999)
Health Hazard
Inhalation or contact with eyes or skin causes irritation. Ingestion causes abdominal pain, nausea, vomiting, pallor, shortness of breath. (USCG, 1999)
Reactivity Profile
Acetic acid or acetic anhydride can explode with permanganates, such as BARIUM PERMANGANATE, if not kept cold [Von Schwartz 1918 p 34]. Explosions can occur when permanganates that have been treated with sulfuric acid come in contact with benzene, carbon disulfide, diethyl ether, ethyl alcohol, petroleum, or organic matter.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

Use caution: Liquids with this reactive group classification have been known to react with the absorbents listed below. More info about absorbents, including situations to watch out for...

  • Cellulose-Based Absorbents
  • Expanded Polymeric Absorbents

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 141 [Oxidizers - Toxic]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

LARGE SPILL: Consider initial downwind evacuation for at least 100 meters (330 feet).

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2020)
Firefighting
Excerpt from ERG Guide 141 [Oxidizers - Toxic]:

SMALL FIRE: Use water. Do not use dry chemicals or foams. CO2 or Halon® may provide limited control.

LARGE FIRE: Flood fire area with water from a distance. Do not move cargo or vehicle if cargo has been exposed to heat. If it can be done safely, move undamaged containers away from the area around the fire.

FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2020)
Non-Fire Response
Excerpt from ERG Guide 141 [Oxidizers - Toxic]:

Keep combustibles (wood, paper, oil, etc.) away from spilled material. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk.

SMALL DRY SPILL: With clean shovel, place material into clean, dry container and cover loosely; move containers from spill area.

LARGE SPILL: Dike far ahead of spill for later disposal. (ERG, 2020)
Protective Clothing
Goggles or face shield; dust respirator; rubber gloves and shoes. (USCG, 1999)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Get medical attention. Alert doctor to possibility of barium poisoning, particularly if compound was swallowed.

INHALATION: remove to fresh air.

EYES: flush with copious amounts of water for 15 min.

SKIN: wash with copious amounts of water.

INGESTION: induce vomiting; give a 10% water solution of Epsom salt. (USCG, 1999)

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.

Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula:
  • Ba(MnO4)2
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: data unavailable
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: 3.77 at 68°F (USCG, 1999) - Denser than water; will sink
Boiling Point: data unavailable
Molecular Weight: 375 (USCG, 1999)
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH: data unavailable

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Barium permanganate (7787-36-2) 20 mg/m3 34 mg/m3 200 mg/m3
(DOE, 2018)

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
Barium Compounds N040 313
Manganese Compounds N450 & 313

(EPA List of Lists, 2022)

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

Chemical Name CAS Number Threshold Quantity (TQ)
Ammonium Permanganate 7787-36-2 7500 pounds

(OSHA, 2019)

This section provides a listing of alternate names for this chemical, including trade names and synonyms.
  • BARIUM PERMANGANATE

Version 3.0.0