Get the app in the App Store and on Google Play!

DICHLOROISOCYANURIC ACID, DRY

5.1 - Oxidizer
Add to MyChemicals

The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number
  • 2782-57-2
DOT Hazard Label USCG CHRIS Code
  • Oxidizer
none
NIOSH Pocket Guide International Chem Safety Card
none none
NFPA 704
Diamond Hazard Value Description
0
3 2
ox
Blue Health 3 Can cause serious or permanent injury.
Red Flammability 0 Will not burn under typical fire conditions.
Yellow Instability 2 Readily undergoes violent chemical changes at elevated temperatures and pressures.
White Special OX Possesses oxidizing properties.
Note: NFPA ratings shown are for potassium dichloro-s-triazinetrione, CAS number 2244-21-5. This is a synonym for the official name of this record.
(NFPA, 2010)
General Description
Dichloroisocyanuric acid, solid is a white crystalline solid with an odor of chlorine. The material itself is noncombustible but if contaminated with a combustible material ignition can result. It will accelerate the burning of combustible materials. Contact with ammonium compounds or hydrated salts can cause a very vigorous chemical reaction. It may vigorously react with small quantities of water releasing chlorine gas. Prolonged exposure to fire or heat of the material may result in the vigorous decomposition of the material and the rupturing of its containers. Material containing less than 39 percent available chlorine will undergo reactions as described above though it may be longer to initiate and the resulting reaction may not be as vigorous. It is used as a dry bleach in household cleaning compounds and swimming pool disinfectants.

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
  • Strong Oxidizing Agent
  • Water-Reactive
Air & Water Reactions
It may vigorously react with small quantities of water releasing chlorine gas.
Fire Hazard
Excerpt from ERG Guide 140 [Oxidizers]:

These substances will accelerate burning when involved in a fire. Some may decompose explosively when heated or involved in a fire. May explode from heat or contamination. Some will react explosively with hydrocarbons (fuels). May ignite combustibles (wood, paper, oil, clothing, etc.). Containers may explode when heated. Runoff may create fire or explosion hazard. (ERG, 2020)
Health Hazard
Excerpt from ERG Guide 140 [Oxidizers]:

Inhalation, ingestion or contact (skin, eyes) with vapors or substance may cause severe injury, burns or death. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may cause environmental contamination. (ERG, 2020)
Reactivity Profile
DICHLOROISOCYANURIC ACID is slightly hygroscopic and is unstable in the presence of DMSO. This is an oxidizing material; it may ignite organic compounds with which it comes in contact. (NTP, 1992)
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

Use caution: Liquids with this reactive group classification have been known to react with the absorbents listed below. More info about absorbents, including situations to watch out for...

  • Cellulose-Based Absorbents
  • Mineral-Based & Clay-Based Absorbents
  • Expanded Polymeric Absorbents
  • Dirt/Earth

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 140 [Oxidizers]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

LARGE SPILL: Consider initial downwind evacuation for at least 100 meters (330 feet).

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. If ammonium nitrate is in a tank, rail car or tank truck and involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, initiate evacuation including emergency responders for 1600 meters (1 mile) in all directions. (ERG, 2020)
Firefighting
Excerpt from ERG Guide 140 [Oxidizers]:

SMALL FIRE: Use water. Do not use dry chemicals or foams. CO2 or Halon® may provide limited control.

LARGE FIRE: Flood fire area with water from a distance. Do not move cargo or vehicle if cargo has been exposed to heat. If it can be done safely, move undamaged containers away from the area around the fire.

FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2020)
Non-Fire Response
Excerpt from ERG Guide 140 [Oxidizers]:

Keep combustibles (wood, paper, oil, etc.) away from spilled material. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Do not get water inside containers.

SMALL DRY SPILL: With clean shovel, place material into clean, dry container and cover loosely; move containers from spill area.

SMALL LIQUID SPILL: Use a non-combustible material like vermiculite or sand to soak up the product and place into a container for later disposal.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. (ERG, 2020)
Protective Clothing
Excerpt from ERG Guide 140 [Oxidizers]:

Wear positive pressure self-contained breathing apparatus (SCBA). Wear chemical protective clothing that is specifically recommended by the manufacturer when there is NO RISK OF FIRE. Structural firefighters' protective clothing provides thermal protection but only limited chemical protection. (ERG, 2020)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
EYES: First check the victim for contact lenses and remove if present. Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center. Do not put any ointments, oils, or medication in the victim's eyes without specific instructions from a physician. IMMEDIATELY transport the victim after flushing eyes to a hospital even if no symptoms (such as redness or irritation) develop.

SKIN: IMMEDIATELY flood affected skin with water while removing and isolating all contaminated clothing. Gently wash all affected skin areas thoroughly with soap and water. If symptoms such as redness or irritation develop, IMMEDIATELY call a physician and be prepared to transport the victim to a hospital for treatment.

INHALATION: IMMEDIATELY leave the contaminated area; take deep breaths of fresh air. If symptoms (such as wheezing, coughing, shortness of breath, or burning in the mouth, throat, or chest) develop, call a physician and be prepared to transport the victim to a hospital. Provide proper respiratory protection to rescuers entering an unknown atmosphere. Whenever possible, Self-Contained Breathing Apparatus (SCBA) should be used; if not available, use a level of protection greater than or equal to that advised under Protective Clothing.

INGESTION: DO NOT INDUCE VOMITING. If the victim is conscious and not convulsing, give 1 or 2 glasses of water to dilute the chemical and IMMEDIATELY call a hospital or poison control center. Be prepared to transport the victim to a hospital if advised by a physician. If the victim is convulsing or unconscious, do not give anything by mouth, ensure that the victim's airway is open and lay the victim on his/her side with the head lower than the body. DO NOT INDUCE VOMITING. IMMEDIATELY transport the victim to a hospital. (NTP, 1992)

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.

Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula:
  • C3HCl2N3O3
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: 437°F (NTP, 1992)
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: data unavailable
Boiling Point: data unavailable
Molecular Weight: 197.97 (NTP, 1992)
Water Solubility: Insoluble (<1 mg/ml at 81°F) (NTP, 1992)
Ionization Energy/Potential: data unavailable
IDLH: data unavailable

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

No PAC information available.

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

No regulatory information available.

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

This section provides a listing of alternate names for this chemical, including trade names and synonyms.
  • ACL 70
  • CDB 60
  • 1,3-DICHLORO-S-TRIAZINE-2,4,6(1H,3H,5H)-TRIONE
  • DICHLORO-S-TRIAZINE-2,4,6-TRIONE
  • 1,3-DICHLORO-S-TRIAZINE-2,4,6-TRIONE
  • DICHLOROCYANURIC ACID
  • DICHLOROISOCYANURATE
  • DICHLOROISOCYANURIC ACID
  • DICHLOROISOCYANURIC ACID, DRY
  • DICHLOROISOCYANURIC ACID, [DRY]
  • FI CLOR 71
  • HILITE 60
  • ISOCYANURIC DICHLORIDE
  • ORCED
  • S-TRIAZINE-2,4,6(1H,3H,5H)-TRIONE, 1,3-DICHLORO-
  • S-TRIAZINE-2,4,6(1H,3H,5H)-TRIONE, DICHLORO-
  • TROCLOSENE

Version 3.0.0