Get the app in the App Store and on Google Play!

HEXACHLOROCYCLOPENTADIENE

6.1 - Poison Inhalation Hazard
Add to MyChemicals

The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number
  • 77-47-4   (HEXACHLOROCYCLOPENTADIENE)
DOT Hazard Label USCG CHRIS Code
  • Poison Inhalation Hazard
NIOSH Pocket Guide International Chem Safety Card
Hexachlorocyclopentadieneexternal_link
NFPA 704
data unavailable
General Description
A pale yellow liquid with a pungent odor. Density 14.3 lb /gal. Solidifies at 50°F. Insoluble in water. Noncombustible. Very toxic by skin absorption and inhalation. Corrosive to tissue.

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
none
Air & Water Reactions
Insoluble in water. Reacts slowly with water to form hydrochloric acid.
Fire Hazard
Toxic hydrogen chloride, chlorine, and phosgene gases may form in fires. In presence of moisture, will corrode iron and other materials; flammable and explosive hydrogen gas may collect in enclosed space. Will corrode iron and other metals in the presence of moisture. Reacts slowly with water to form hydrochloric acid; however, the reaction is not hazardous. Hazardous polymerization may not occur. (EPA, 1998)
Health Hazard
This compound is very toxic and may be fatal if inhaled, swallowed, or absorbed through the skin. The probable human lethal dose is 50-500 mg/kg, or between 1 teaspoon and 1 ounce for a 150 lb. (70 kg) person. Severe exposure induces pulmonary hyperemia and edema, degenerative and necrotic changes in brain, heart and adrenal glands and necrosis of liver and kidney tubules. (EPA, 1998)
Reactivity Profile
HEXACHLOROCYCLOPENTADIENE is incompatible with strong oxidizing and reducing agents. Also incompatible with many amines, nitrides, azo/diazo compounds, alkali metals (sodium), and epoxides.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

Use caution: Liquids with this reactive group classification have been known to react with the absorbent listed below. More info about absorbents, including situations to watch out for...

  • Dirt/Earth

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 151 [Substances - Toxic (Non-Combustible)]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

SPILL: See ERG Table 1 - Initial Isolation and Protective Action Distances on the UN/NA 2646 datasheet.

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2020)
Firefighting
Isolate hazard area and deny entry. Wear positive pressure breathing apparatus and special protective clothing. Fight fire from maximum distance. Dike fire control water for later disposal.

Use dry chemical, carbon dioxide, water spray or foam for small fires. For large fires, use water spray, fog, or foam. Move hexachlorocyclopentadiene from fire area if this can be done without risk. (EPA, 1998)
Non-Fire Response
Excerpt from ERG Guide 151 [Substances - Toxic (Non-Combustible)]:

Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. Cover with plastic sheet to prevent spreading. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. DO NOT GET WATER INSIDE CONTAINERS. (ERG, 2020)
Protective Clothing
Excerpt from NIOSH Pocket Guide for Hexachlorocyclopentadieneexternal link:

Skin: PREVENT SKIN CONTACT - Wear appropriate personal protective clothing to prevent skin contact.

Eyes: PREVENT EYE CONTACT - Wear appropriate eye protection to prevent eye contact.

Wash skin: WHEN CONTAMINATED - The worker should immediately wash the skin when it becomes contaminated.

Remove: WHEN WET OR CONTAMINATED - Work clothing that becomes wet or significantly contaminated should be removed and replaced.

Change: No recommendation is made specifying the need for the worker to change clothing after the workshift.

Provide:
• EYEWASH - Eyewash fountains should be provided in areas where there is any possibility that workers could be exposed to the substances; this is irrespective of the recommendation involving the wearing of eye protection.
• QUICK DRENCH - Facilities for quickly drenching the body should be provided within the immediate work area for emergency use where there is a possibility of exposure. [Note: It is intended that these facilities provide a sufficient quantity or flow of water to quickly remove the substance from any body areas likely to be exposed. The actual determination of what constitutes an adequate quick drench facility depends on the specific circumstances. In certain instances, a deluge shower should be readily available, whereas in others, the availability of water from a sink or hose could be considered adequate.] (NIOSH, 2023)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Warning: Effects may be delayed. Caution is advised. Vital signs should be monitored closely.

Signs and Symptoms of Hexachlorocyclopentadiene Exposure: Signs and symptoms of acute hexachlorocyclopentadiene exposure include headache, nausea, cough, throat irritation, difficult breathing, chest discomfort, bronchitis, and pulmonary edema. Inhalation of hexachlorocyclopentadiene mist is highly irritating to mucous membranes, causing tearing, sneezing, and salivation. Contact with hexachlorocyclopentadiene may result in severe eye irritation and blistering and burning of the skin.

Emergency Life-Support Procedures: Acute exposure to hexachlorocyclopentadiene may require decontamination and life support for the victims. Emergency personnel should wear protective clothing appropriate to the type and degree of contamination. Air-purifying or supplied-air respiratory equipment should also be worn, as necessary. Rescue vehicles should carry supplies such as plastic sheeting and disposable plastic bags to assist in preventing spread of contamination.

Inhalation Exposure:
1. Move victims to fresh air. Emergency personnel should avoid self-exposure to hexachlorocyclopentadiene.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
3. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
4. Rush to a health care facility.

Dermal/Eye Exposure:
1. Remove victims from exposure. Emergency personnel should avoid self-exposure to hexachlorocyclopentadiene.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
3. Remove and isolate contaminated clothing as soon as possible.
4. If eye exposure has occurred, eyes must be flushed with lukewarm water for at least 15 minutes.
5. Wash exposed skin areas thoroughly with soap and water.
6. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
7. Rush to a health care facility.

Ingestion Exposure:
1. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
2. DO NOT induce vomiting or attempt to neutralize!
3. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
4. Activated charcoal may be administered if victims are conscious and alert. Use 15 to 30 g (1/2 to 1 oz) for children, 50 to 100 g (1-3/4 to 3-1/2 oz) for adults, with 125 to 250 mL (1/2 to 1 cup) of water.
5. Promote excretion by administering a saline cathartic or sorbitol to conscious and alert victims. Children require 15 to 30 g (1/2 to 1 oz) of cathartic; 50 to 100 g (1-3/4 to 3-1/2, oz) is recommended for adults.
6. Rush to a health care facility. (EPA, 1998)

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.

Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula:
  • C5Cl6
Flash Point: Non-flammable (EPA, 1998)
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: 16°F (EPA, 1998)
Vapor Pressure: 0.08 mmHg at 77°F (EPA, 1998)
Vapor Density (Relative to Air): 9.4 (EPA, 1998) - Heavier than air; will sink
Specific Gravity: 1.7019 at 77°F (EPA, 1998) - Denser than water; will sink
Boiling Point: 462°F at 753 mmHg (EPA, 1998)
Molecular Weight: 272.77 (EPA, 1998)
Water Solubility: less than 0.1 mg/mL at 70.7°F (NTP, 1992)
Ionization Energy/Potential: data unavailable
IDLH: data unavailable

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Hexachlorocylopentadiene (77-47-4) 0.03 ppm 0.55 ppm 1 ppm
(DOE, 2018)

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
Hexachlorocyclopentadiene 77-47-4 100 pounds 10 pounds 10 pounds 313 U130

(EPA List of Lists, 2022)

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

This section provides a listing of alternate names for this chemical, including trade names and synonyms.
  • C 56
  • C-56
  • 1,3-CYCLOPENTADIENE, 1,2,3,4,5,5-HEXACHLORO-
  • GRAPHLOX
  • HCCPD
  • HEXACHLORO-1,3-CYCLOPENTADIENE
  • 1,2,3,4,5,5-HEXACHLORO-1,3-CYCLOPENTADIENE
  • HEXACHLOROCYCLOPENTADIEN
  • HEXACHLOROCYCLOPENTADIENE
  • HEXACHLOROPENTADIENE
  • HRS 1655
  • NCI-C55607
  • PCL
  • PERCHLOROCYCLOPENTADIENE

Version 3.0.0