SODIUM CYANIDE

6.1 - Poison
Add to MyChemicals

The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number
  • 143-33-9
DOT Hazard Label USCG CHRIS Code
  • Poison
NIOSH Pocket Guide International Chem Safety Card
Sodium cyanide (as CN)external_link
NFPA 704
Diamond Hazard Value Description
0
3 0
Blue Health 3 Can cause serious or permanent injury.
Red Flammability 0 Will not burn under typical fire conditions.
Yellow Instability 0 Normally stable, even under fire conditions.
White Special
(NFPA, 2010)
General Description
A white crystalline solid, lump solid or powder. A deadly human poison by ingestion. Toxic by skin absorption through open wounds, by ingestion, and by inhalation of dust.

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
  • Water-Reactive
Air & Water Reactions
Deliquescent. Soluble in water. Slowly decomposed by water and very rapidly by acids to give off hydrogen cyanide, a flammable poison gas.

Based on a scenario where the chemical is spilled into an excess of water (at least 5 fold excess of water), half of the maximum theoretical yield of Hydrogen Cyanide gas will be created in 12 minutes. Experimental details are in the following: "Development of the Table of Initial Isolation and Protective Distances for the 2008 Emergency Response Guidebook", ANL/DIS-09-2, D.F. Brown, H.M. Hartmann, W.A. Freeman, and W.D. Haney, Argonne National Laboratory, Argonne, Illinois, June 2009.
Fire Hazard
Sodium cyanide is not combustible itself, but contact with acids releases highly flammable hydrogen cyanide gas. Fire may produce irritating or poisonous gases. Runoff from fire control water may give off poisonous gases. Container may explode in the heat of fire. Avoid strong oxidizers such as nitrates and chlorates; acids and acid salts. Avoid contact with acids. Aqueous solutions rapidly decompose. (EPA, 1998)
Health Hazard
Super toxic; probable oral lethal dose in humans is less than 5 mg/kg or a taste (less than 7 drops) for a 70 kg (150 lb.) person. Sodium cyanide is poisonous and may be fatal if inhaled, swallowed or absorbed through the skin. Contact with sodium cyanide may cause burns to skin and eyes. Individuals with chronic diseases of the kidneys, respiratory tract, skin, or thyroid are at greater risk of developing toxic cyanide effects. (EPA, 1998)
Reactivity Profile
SODIUM CYANIDE produces deadly and flammable hydrogen cyanide gas pon contact with acids, even very weak acids , e.g., carbon dioxide dissolved in water (soda pop). Reacts violently with fluorine, magnesium, nitric acid, nitrates and nitrites [Sax, 9th ed., 1996, p. 2958]. Incompatible with strong oxidizing agents.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

No information available.

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters (75 feet) for solids.

SPILL: See ERG Table 1 - Initial Isolation and Protective Action Distances on the UN/NA 1689 datasheet.

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2024)
Firefighting
Full protective clothing including self-contained breathing apparatus, rubber gloves, boots, and bands around legs, arms, and waist should be provided. No skin surface should be exposed. Normal fire fighting procedures may be used.

Fight fire from maximum distance. Move container from area if you can do it without risk. Dike fire control water for later disposal. Do not scatter the material.

Use water. Use dry chemical, carbon dioxide, water spray, or foam for small fires, water spray, fog, or foam for large fires. (EPA, 1998)
Non-Fire Response
Excerpt from ERG Guide 157 [Substances - Toxic and/or Corrosive (Non-Combustible / Water-Sensitive)]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Stop leak if you can do it without risk. A vapor-suppressing foam may be used to reduce vapors. DO NOT GET WATER INSIDE CONTAINERS. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. Prevent entry into waterways, sewers, basements or confined areas.

SMALL SPILL: Cover with DRY earth, DRY sand or other non-combustible material followed with plastic sheet to minimize spreading or contact with rain. Use clean, non-sparking tools to collect material and place it into loosely covered plastic containers for later disposal. (ERG, 2024)
Protective Clothing
Excerpt from NIOSH Pocket Guide for Sodium cyanide (as CN)external link:

Skin: PREVENT SKIN CONTACT - Wear appropriate personal protective clothing to prevent skin contact.

Eyes: PREVENT EYE CONTACT - Wear appropriate eye protection to prevent eye contact.

Wash skin: WHEN CONTAMINATED - The worker should immediately wash the skin when it becomes contaminated.

Remove: WHEN WET OR CONTAMINATED - Work clothing that becomes wet or significantly contaminated should be removed and replaced.

Change: DAILY - Workers whose clothing may have become contaminated should change into uncontaminated clothing before leaving the work premises.

Provide:
• EYEWASH - Eyewash fountains should be provided in areas where there is any possibility that workers could be exposed to the substances; this is irrespective of the recommendation involving the wearing of eye protection.
• QUICK DRENCH - Facilities for quickly drenching the body should be provided within the immediate work area for emergency use where there is a possibility of exposure. [Note: It is intended that these facilities provide a sufficient quantity or flow of water to quickly remove the substance from any body areas likely to be exposed. The actual determination of what constitutes an adequate quick drench facility depends on the specific circumstances. In certain instances, a deluge shower should be readily available, whereas in others, the availability of water from a sink or hose could be considered adequate.] (NIOSH, 2024)
DuPont Tychem® Suit Fabrics
Tychem® Fabric Legend
QS = Tychem 2000 SFR
QC = Tychem 2000
SL = Tychem 4000
C3 = Tychem 5000
TF = Tychem 6000
TP = Tychem 6000 FR
RC = Tychem RESPONDER® CSM
TK = Tychem 10000
RF = Tychem 10000 FR
Testing Details
The fabric permeation data was generated for DuPont by a third party laboratory. Permeation data for industrial chemicals is obtained per ASTM F739. Normalized breakthrough times (the time at which the permeation rate exceeds 0.1 μg/cm2/min) are reported in minutes. All chemicals have been tested between approximately 20°C and 27°C unless otherwise stated. All chemicals have been tested at a concentration of greater than 95% unless otherwise stated.
Chemical warfare agents (Lewisite, Sarin, Soman, Sulfur Mustard, Tabun and VX Nerve Agent) have been tested at 22°C and 50% relative humidity per military standard MIL-STD-282. "Breakthrough time" for chemical warfare agents is defined as the time when the cumulative mass which permeated through the fabric exceeds the limit in MIL-STD-282 [either 1.25 or 4.0 μg/cm2].
A Caution from DuPont
This information is based upon technical data that DuPont believes to be reliable on the date issued. It is subject to revision as additional knowledge and experience are gained. The information reflects laboratory performance of fabrics, not complete garments, under controlled conditions. It is intended for informational use by persons having technical skill for evaluation under their specific end-use conditions, at their own discretion and risk. It is the user's responsibility to determine the level of toxicity and the proper personal protective equipment needed. Anyone intending to use this information should first verify that the garment selected is suitable for the intended use. In many cases, seams and closures have shorter breakthrough times and higher permeation rates than the fabric. If fabric becomes torn,abraded or punctured, or if seams or closures fail, or if attached gloves, visors, etc. are damaged, end user should discontinue use of garment to avoid potential exposure to chemical. Since conditions of use are outside our control, DuPont makes no warranties, express or implied, including, without limitation, no warranties of merchantability or fitness for a particular use and assume no liability in connection with any use of this information. This information is not intended as a license to operate under or a recommendation to infringe any patent, trademark or technical information of DuPont or others covering any material or its use.
Normalized Breakthrough Times (in Minutes)
Chemical CAS Number State QS QC SL C3 TF TP RC TK RF
Sodium cyanide (45%) 143-33-9 Liquid >480 >480 >480 >480 >480
Sodium cyanide (sat) 143-33-9 Liquid >480 >480 >480 >480
> indicates greater than.

Special Warning from DuPont: Tychem® and Tyvek® fabrics should not be used around heat, flames, sparks or in potentially flammable or explosive environments. Only...

...Tychem® ThermoPro, Tychem® Reflector® and Tychem® TK styles 600T/601T (with aluminized outer suit) garments are designed and tested to help reduce burn injury during escape from a flash fire. Users of Tychem® ThermoPro, Tychem® Reflector® and Tychem® TK styles 600T/601T (with aluminized outer suit) garments should not knowingly enter an explosive environment. Tychem® garments with attached socks must be worn inside protective outer footwear and are not suitable as outer footwear. These attached socks do not have adequate durability or slip resistance to be worn as the outer foot covering.

(DuPont, 2024)

First Aid
Warning: Heart palpitations may occur within minutes after exposure. Caution is advised. Effects may be delayed.

Signs and Symptoms of Acute Sodium Cyanide Exposure: Signs and symptoms of acute exposure to sodium cyanide may include hypertension (high blood pressure) and tachycardia (rapid heart rate), followed by hypotension (low blood pressure) and bradycardia (slow heart rate). Cardiac arrhythmias and other cardiac abnormalities are common. Cyanosis (blue tint to the skin and mucous membranes) and cherry-red or bloody mucous membranes may occur. Tachypnea (rapid respiratory rate) may be followed by respiratory depression. Pulmonary edema and lung hemorrhage may also occur. Headache, vertigo (dizziness), agitation, and giddiness may be followed by combative behavior, dilated and unreactive pupils, convulsions, paralysis, and coma. Sodium cyanide is irritating to the skin and mucous membranes. Lacrimation (tearing) and a burning sensation of the mouth and throat are common. Increased salivation, nausea, and vomiting are often seen.

Emergency Life-Support Procedures: Acute exposure to sodium cyanide may require decontamination and life support for the victims. All exposed persons should be transported to a health care facility as quickly as possible. Emergency personnel should wear protective clothing appropriate to the type and degree of contamination. Air-purifying or supplied-air respiratory equipment should also be worn as necessary. Rescue vehicles should carry supplies such as plastic sheeting and disposable plastic bags to assist in preventing spread of contamination.

Inhalation Exposure:
1. Move victims to fresh air. Emergency personnel should avoid self-exposure to sodium cyanide.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. IMMEDIATELY begin administering 100% oxygen to all victims. Monitor victims for respiratory distress.Warning: To prevent self-poisoning, avoid mouth-to-mouth breathing; use a forced-oxygen mask. Direct oral contact with sodium cyanide-contaminated persons or their gastric contents may result in self-poisoning.
3. RUSH to a health care facility!
4. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.

Dermal/Eye Exposure:
1. Remove victims from exposure. Emergency personnel should avoid self- exposure to sodium cyanide.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. IMMEDIATELY begin administering 100% oxygen to all victims. Monitor victims for respiratory distress.Warning: To prevent self-poisoning, avoid mouth-to-mouth breathing; use a forced-oxygen mask. Direct oral contact with sodium cyanide-contaminated persons or their gastric contents may result in self-poisoning.
3. RUSH to a health care facility!
4. Remove contaminated clothing as soon as possible.
5. If eye exposure has occurred, eyes must be flushed with lukewarm water for at least 15 minutes.
6. Wash exposed skin areas twice with soap and water.
7. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.

Ingestion Exposure:
1. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. IMMEDIATELY begin administering 100% oxygen to all victims. Monitor victims for respiratory distress.Warning: To prevent self-poisoning, avoid mouth-to-mouth breathing; use a forced-oxygen mask. Direct oral contact with sodium cyanide-contaminated persons or their gastric contents may result in self-poisoning.
2. RUSH to a health care facility!
3. DO NOT induce vomiting. Ipecac is not recommended for ingestion of sodium cyanide.
4. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
5. Activated charcoal may be administered if victims are conscious and alert. Use 15 to 30 g (1/2 to 1 oz) for children, 50 to 100 g (1-3/4 to 3-1/2 oz) for adults, with 125 to 250 mL (1/2 to 1 cup) of water.
6. Promote excretion by administering a saline cathartic or sorbitol to conscious and alert victims. Children require 15 to 30 g (1/2 to 1 oz) of cathartic; 50 to 100 g (1-3/4 to 3-1/2 oz) is recommended for adults. (EPA, 1998)

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.

Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula:
  • CNNa
Flash Point: Not combustible (EPA, 1998)
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: Not flammable (USCG, 1999)
Melting Point: 1047°F (EPA, 1998)
Vapor Pressure: 1 mmHg at 1502.6°F (EPA, 1998)
Vapor Density (Relative to Air): data unavailable
Specific Gravity: 1.6 at 77°F (USCG, 1999) - Denser than water; will sink
Boiling Point: 2725°F at 760 mmHg (EPA, 1998)
Molecular Weight: 49.01 (EPA, 1998)
Water Solubility: greater than or equal to 100 mg/mL at 68°F (NTP, 1992)
Ionization Energy/Potential: data unavailable
IDLH: 25 mg CN/m3 (NIOSH, 2024)

AEGLs (Acute Exposure Guideline Levels)

Final AEGLs for Sodium cyanide (143-33-9)
Exposure Period AEGL-1 AEGL-2 AEGL-3
10 minutes 5 mg/m3 34 mg/m3 54 mg/m3
30 minutes 5 mg/m3 20 mg/m3 42 mg/m3
60 minutes 4 mg/m3 14 mg/m3 30 mg/m3
4 hours 2.6 mg/m3 7 mg/m3 17 mg/m3
8 hours 2 mg/m3 5 mg/m3 13 mg/m3
(NAC/NRC, 2024)

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Sodium cyanide (143-33-9) 4 mg/m3 14 mg/m3 30 mg/m3
(DOE, 2024)

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
Cyanide Compounds N106 & 313
Sodium cyanide (Na(CN)) 143-33-9 100 pounds 10 pounds 10 pounds 313c P106

(EPA List of Lists, 2024)

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

RELEASE THEFT SABOTAGE
Chemical of Interest CAS Number Min Conc STQ Security
Issue
Min Conc STQ Security
Issue
Min Conc STQ Security
Issue
Sodium cyanide 143-33-9 ACG APA sabotage/ contamination

(CISA, 2007)

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

This section provides a listing of alternate names for this chemical, including trade names and synonyms.
  • CYANASALT H
  • CYANASALT S
  • CYANIDE OF SODIUM
  • CYANOBRIK
  • CYANOGRAN
  • CYMAG
  • HYDROCYANIC ACID, SODIUM SALT
  • NATRIUM CYANIDE
  • SODIUM CYANIDE
  • SODIUM CYANIDE (NA(CN))
  • SODIUM CYANIDE(NA(CN))
  • SODIUM CYANIDE, [SOLID]
  • SODIUM SALT OF HYDROCYANIC ACID