Get the app in the App Store and on Google Play!

AMMONIA, ANHYDROUS

2.2 - Non-flammable, non-poisonous gas Inhalation Hazard (Special Provision 13) (domestic) 2.3 - Poisonous gas 8 - Corrosive
Add to MyChemicals

The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number
  • 7664-41-7   (AMMONIA)
DOT Hazard Label USCG CHRIS Code
  • Non-Flammable Gas (domestic)
  • Inhalation Hazard (Special Provision 13) (domestic)
  • Poison Gas (international)
  • Corrosive (international)
NIOSH Pocket Guide International Chem Safety Card
Ammoniaexternal_link
NFPA 704
Diamond Hazard Value Description
1
3 0
Blue Health 3 Can cause serious or permanent injury.
Red Flammability 1 Must be preheated before ignition can occur.
Yellow Instability 0 Normally stable, even under fire conditions.
White Special
Note: The Refrigeration System Classification section of the International Mechanical Code requires a value of 3 for the red quadrant (flammability hazard) for indoor ammonia refrigeration equipment.
(NFPA, 2010)
General Description
A clear colorless gas with a strong odor. Shipped as a liquid under its own vapor pressure. Density (liquid) 6 lb / gal. Contact with the unconfined liquid can cause frostbite. Gas generally regarded as nonflammable but does burn within certain vapor concentration limits and with strong ignition. Fire hazard increases in the presence of oil or other combustible materials. Although gas is lighter than air, vapors from a leak initially hug the ground. Prolonged exposure of containers to fire or heat may cause violent rupturing and rocketing. Long-term inhalation of low concentrations of the vapors or short-term inhalation of high concentrations has adverse health effects. Used as a fertilizer, as a refrigerant, and in the manufacture of other chemicals.

Rate of onset: Immediate

Persistence: Minutes

Odor threshold: 17 ppm

Source/use/other hazard: Explosives manufacture; pesticides; detergents industry.

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
  • Water-Reactive
Air & Water Reactions
Soluble in water with evolution of heat. The amount of heat generated may be large.
Fire Hazard
Mixing of ammonia with several chemicals can cause severe fire hazards and/or explosions. Ammonia in container may explode in heat of fire. Incompatible with many materials including silver and gold salts, halogens, alkali metals, nitrogen trichloride, potassium chlorate, chromyl chloride, oxygen halides, acid vapors, azides, ethylene oxide, picric acid and many other chemicals. Mixing with other chemicals and water. Hazardous polymerization may not occur. (EPA, 1998)
Health Hazard
Vapors cause irritation of eyes and respiratory tract. Liquid will burn skin and eyes. Poisonous; may be fatal if inhaled. Contact may cause burns to skin and eyes. Contact with liquid may cause frostbite. (EPA, 1998)
Reactivity Profile
AMMONIA is a base. Reacts exothermically with all acids. Violent reactions are possible. Readily combines with silver oxide or mercury to form compounds that explode on contact with halogens. When in contact with chlorates it forms explosive ammonium chlorate [Kirk-Othmer, 3rd ed., Vol. 2, 1978, p. 470]. Reacts violently or produces explosive products with fluorine, chlorine, bromine and iodine and some of the interhalogen compounds (bromine pentafluoride, chlorine trifluoride). Mixing of bleaching powder (hypochlorite solution) with ammonia solutions produces toxic/explosive ammonia trichloride vapors. Undergoes potentially violent or explosive reactions on contact with 1,2-dichloroethane (with liquid ammonia), boron halides, ethylene oxide (polymerization), perchlorates or strong oxidants (chromyl chloride, chromium trioxide, chromic acid, nitric acid, hydrogen peroxide, chlorates, fluorine, nitrogen oxide, liquid oxygen). Reacts with silver chloride, silver oxide, silver nitrate or silver azide to form the explosive silver nitride. May react with some heavy metal compounds (mercury, gold(III) chloride) to produce materials that may explode when dry. [Bretherick, 5th ed., 1995, p. 1553].
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

No information available.

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 125 [Gases - Toxic and/or Corrosive]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 100 meters (330 feet) in all directions.

SPILL: See ERG Tables 1 and 3 - Initial Isolation and Protective Action Distances on the UN/NA 1005 datasheet.

FIRE: If tank, rail tank car or highway tank is involved in a fire, ISOLATE for 1600 meters (1 mile) in all directions; also, consider initial evacuation for 1600 meters (1 mile) in all directions. (ERG, 2024)
Firefighting
Wear positive pressure breathing apparatus and full protective clothing.

Small fires: dry chemical or carbon dioxide. Large fires: water spray, fog or foam. Apply water gently to the surface. Do not get water inside container. Move container from fire area if you can do it without risk. Stay away from ends of tanks. Cool containers that are exposed to flames with water from the side until well after fire is out. Isolate area until gas has dispersed. (EPA, 1998)
Non-Fire Response
Excerpt from ERG Guide 125 [Gases - Toxic and/or Corrosive]:

Do not touch or walk through spilled material. Stop leak if you can do it without risk. If possible, turn leaking containers so that gas escapes rather than liquid. Prevent entry into waterways, sewers, basements or confined areas. Do not direct water at spill or source of leak. Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material. Isolate area until gas has dispersed. (ERG, 2024)
Protective Clothing
For emergency situations, wear a positive pressure, pressure-demand, full facepiece self-contained breathing apparatus (SCBA) or pressure- demand supplied air respirator with escape SCBA and a fully-encapsulating, chemical resistant suit. (EPA, 1998)
DuPont Tychem® Suit Fabrics
Tychem® Fabric Legend
QS = Tychem 2000 SFR
QC = Tychem 2000
SL = Tychem 4000
C3 = Tychem 5000
TF = Tychem 6000
TP = Tychem 6000 FR
RC = Tychem RESPONDER® CSM
TK = Tychem 10000
RF = Tychem 10000 FR
Testing Details
The fabric permeation data was generated for DuPont by a third party laboratory. Permeation data for industrial chemicals is obtained per ASTM F739. Normalized breakthrough times (the time at which the permeation rate exceeds 0.1 μg/cm2/min) are reported in minutes. All chemicals have been tested between approximately 20°C and 27°C unless otherwise stated. All chemicals have been tested at a concentration of greater than 95% unless otherwise stated.
Chemical warfare agents (Lewisite, Sarin, Soman, Sulfur Mustard, Tabun and VX Nerve Agent) have been tested at 22°C and 50% relative humidity per military standard MIL-STD-282. "Breakthrough time" for chemical warfare agents is defined as the time when the cumulative mass which permeated through the fabric exceeds the limit in MIL-STD-282 [either 1.25 or 4.0 μg/cm2].
A Caution from DuPont
This information is based upon technical data that DuPont believes to be reliable on the date issued. It is subject to revision as additional knowledge and experience are gained. The information reflects laboratory performance of fabrics, not complete garments, under controlled conditions. It is intended for informational use by persons having technical skill for evaluation under their specific end-use conditions, at their own discretion and risk. It is the user's responsibility to determine the level of toxicity and the proper personal protective equipment needed. Anyone intending to use this information should first verify that the garment selected is suitable for the intended use. In many cases, seams and closures have shorter breakthrough times and higher permeation rates than the fabric. If fabric becomes torn,abraded or punctured, or if seams or closures fail, or if attached gloves, visors, etc. are damaged, end user should discontinue use of garment to avoid potential exposure to chemical. Since conditions of use are outside our control, DuPont makes no warranties, express or implied, including, without limitation, no warranties of merchantability or fitness for a particular use and assume no liability in connection with any use of this information. This information is not intended as a license to operate under or a recommendation to infringe any patent, trademark or technical information of DuPont or others covering any material or its use.
Normalized Breakthrough Times (in Minutes)
Chemical CAS Number State QS QC SL C3 TF TP RC TK RF
Ammonia (-33°C, liquid) 7664-41-7 Liquid 35 20 30 >480
Ammonia (-70°C, liquid) 7664-41-7 Liquid >480 >480 >480
Ammonia (gaseous) 7664-41-7 Vapor imm imm 26 imm 20 90 105*/133 >480 >480
> indicates greater than.
"imm" indicates immediate; having a normalized breakthrough time of 10 minutes or less.
* indicates based on lowest single value.

Special Warning from DuPont: Tychem® and Tyvek® fabrics should not be used around heat, flames, sparks or in potentially flammable or explosive environments. Only...

...Tychem® ThermoPro, Tychem® Reflector® and Tychem® TK styles 600T/601T (with aluminized outer suit) garments are designed and tested to help reduce burn injury during escape from a flash fire. Users of Tychem® ThermoPro, Tychem® Reflector® and Tychem® TK styles 600T/601T (with aluminized outer suit) garments should not knowingly enter an explosive environment. Tychem® garments with attached socks must be worn inside protective outer footwear and are not suitable as outer footwear. These attached socks do not have adequate durability or slip resistance to be worn as the outer foot covering.

(DuPont, 2024)

First Aid
Warning: Ammonia is extremely corrosive to the skin, eyes, and mucous membranes. Contact with the liquified gas may cause frostbite. Caution is advised.

Signs and Symptoms of Acute Ammonia Exposure: Inhalation of ammonia may cause irritation and burns of the respiratory tract, laryngitis, dyspnea (shortness of breath), stridor (high-pitched respirations), and chest pain. Pulmonary edema and pneumonia may also result from inhalation. A pink frothy sputum, convulsions, and coma are often seen following exposure to high concentrations. When ammonia is ingested, nausea and vomiting may result; oral, esophageal, and stomach burns are common. If ammonia has contacted the eyes, irritation, pain, conjunctivitis (red, inflamed eyes), lacrimation (tearing), and corneal erosion may occur. Loss of vision is possible. Dermal exposure may result in severe burns and pain.

Emergency Life-Support Procedures: Acute exposure to ammonia may require decontamination and life support for the victims. Emergency personnel should wear protective clothing appropriate to the type and degree of contamination. Air-purifying or supplied-air respiratory equipment should also be worn, as necessary.

Inhalation Exposure:
1. Move victims to fresh air. Emergency personnel should avoid self-exposure to ammonia.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
3. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
4. Transport to a health care facility.

Dermal/Eye Exposure:
1. Remove victims from exposure. Emergency personnel should avoid self- exposure to ammonia.
2. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.Warning: Do not attempt to neutralize with an acid wash; excessive liberation of heat may result.
3. If eye exposure has occurred, eyes must IMMEDIATELY be flushed with lukewarm water for at least 15 minutes.
4. Remove contaminated clothing as soon as possible.
5. Wash exposed skin areas THOROUGHLY with soap and water.
6. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
7. Transport to a health care facility.

Ingestion Exposure:
1. Evaluate vital signs including pulse and respiratory rate, and note any trauma. If no pulse is detected, provide CPR. If not breathing, provide artificial respiration. If breathing is labored, administer oxygen or other respiratory support.
2. DO NOT induce vomiting or attempt to neutralize!
3. Obtain authorization and/or further instructions from the local hospital for administration of an antidote or performance of other invasive procedures.
4. Activated charcoal does not strongly bind ammonia, and therefore is of little or no value.
5. Give the victims water or milk: children up to 1 year old, 125 mL (4 oz or 1/2 cup); children 1 to 12 years old, 200 mL (6 oz or 3/4 cup); adults, 250 mL (8 oz or 1 cup). Water or milk should be given only if victims are conscious and alert.
6. Transport to a health care facility. (EPA, 1998)

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.

Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula:
  • H3N
Flash Point: data unavailable
Lower Explosive Limit (LEL): 16 % (EPA, 1998)
Upper Explosive Limit (UEL): 25 % (EPA, 1998)
Autoignition Temperature: 1204°F (USCG, 1999)
Melting Point: -107.9°F (EPA, 1998)
Vapor Pressure: 400 mmHg at -49.72°F (EPA, 1998)
Vapor Density (Relative to Air): 0.6 (EPA, 1998) - Lighter than air; will rise
Specific Gravity: 0.6818 at -28.03°F (EPA, 1998) - Less dense than water; will float
Boiling Point: -28.03°F at 760 mmHg (EPA, 1998)
Molecular Weight: 17.03 (EPA, 1998)
Water Solubility: 34 % (NIOSH, 2024)
Ionization Energy/Potential: 10.18 eV (NIOSH, 2024)
IDLH: 300 ppm (NIOSH, 2024)

AEGLs (Acute Exposure Guideline Levels)

Final AEGLs for Ammonia (7664-41-7)
Exposure Period AEGL-1 AEGL-2 AEGL-3
10 minutes 30 ppm 220 ppm 2700 ppm
30 minutes 30 ppm 220 ppm 1600 ppm
60 minutes 30 ppm 160 ppm 1100 ppm
4 hours 30 ppm 110 ppm 550 ppm
8 hours 30 ppm 110 ppm 390 ppm
(NAC/NRC, 2024)

ERPGs (Emergency Response Planning Guidelines)

Chemical ERPG-1 ERPG-2 ERPG-3
Ammonia (7664-41-7) 25 ppm star-in-circle icon indicates that odor should be detectable near ERPG-1. 150 ppm 1500 ppm
star-in-circle icon indicates that odor should be detectable near ERPG-1.
(AIHA, 2022)

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Ammonia (7664-41-7) 30 ppm 160 ppm 1100 ppm LEL = 150000 ppm
(DOE, 2024)

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
Ammonia 7664-41-7 500 pounds 100 pounds 100 pounds
Ammonia (anhydrous) 7664-41-7 500 pounds 100 pounds 100 pounds X 10000 pounds
Ammonia (conc 20% or greater) 7664-41-7 See ammonium hydroxide X 20000 pounds
Ammonia (includes anhydrous ammonia and aqueous ammonia from water dissociable ammonium salts and other sources; 10 percent of total aqueous ammonia is reportable under this listing) 7664-41-7 313

(EPA List of Lists, 2024)

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

RELEASE THEFT SABOTAGE
Chemical of Interest CAS Number Min Conc STQ Security
Issue
Min Conc STQ Security
Issue
Min Conc STQ Security
Issue
Ammonia (anhydrous) 7664-41-7 1.00 % 10000 pounds toxic
Ammonia (conc. 20% or greater) 7664-41-7 20.00 % 20000 pounds toxic

(CISA, 2007)

OSHA Process Safety Management (PSM) Standard List

Chemical Name CAS Number Threshold Quantity (TQ)
Ammonia solutions (>44% ammonia by weight) 7664-41-7 15000 pounds
Ammonia, Anhydrous 7664-41-7 10000 pounds

(OSHA, 2019)

This section provides a listing of alternate names for this chemical, including trade names and synonyms.
  • AM-FOL
  • AMMONIA
  • AMMONIA (ANHYDROUS)
  • AMMONIA (ANHYDROUS) (LIQUEFIED)
  • AMMONIA GAS
  • AMMONIA SOLUTION, WITH MORE THAN 50% AMMONIA
  • AMMONIA, ANHYDROUS
  • AMMONIA, ANHYDROUS, LIQUEFIED
  • AMMONIA, [ANHYDROUS]
  • AMMONIA-14N
  • ANHYDROUS AMMONIA
  • ANHYDROUS AMMONIA, LIQUEFIED
  • AQUA AMMONIA
  • AQUEOUS AMMONIA
  • LIQUID AMMONIA
  • NITRO-SIL
  • R 717
  • REFRIGERENT R717
  • SPIRIT OF HARTSHORN

Contact Us | Website Satisfaction Surveyexternal_link