ALLYL BROMIDE

3 - Flammable liquid 6.1 - Poison
Add to MyChemicals

The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number
  • 106-95-6   (ALLYL BROMIDE)
DOT Hazard Label USCG CHRIS Code
  • Flammable Liquid
  • Poison
NIOSH Pocket Guide International Chem Safety Card
none none
NFPA 704
Diamond Hazard Value Description
3
3 1
Blue Health 3 Can cause serious or permanent injury.
Red Flammability 3 Can be ignited under almost all ambient temperature conditions.
Yellow Instability 1 Normally stable but can become unstable at elevated temperatures and pressures.
White Special
(NFPA, 2010)
General Description
A clear colorless to light yellow liquid with an irritating unpleasant odor. Flash point 30°F. Irritates eyes, skin, and respiratory system. Toxic by skin absorption. Denser than water and slightly soluble in water.

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
  • Highly Flammable
  • Polymerizable
  • Strong Reducing Agent
Air & Water Reactions
Highly flammable. Slightly soluble in water.
Fire Hazard
Special Hazards of Combustion Products: Toxic hydrogen bromide and bromine gases formed in fire.

Behavior in Fire: Vapor is heavier than air and may travel a considerable distance to a source of ignition and flash back. (USCG, 1999)
Health Hazard
Inhalation of vapor irritates mucous membranes and causes dizziness, headache, and lung irritation. Contact with liquid irritates eyes and skin. Ingestion causes irritation of mouth and stomach. (USCG, 1999)
Reactivity Profile
ALLYL BROMIDE decomposes upon heating and exposure to light, forming HBr (a strong reducing agent). Reacts violently with oxidizing agents. Can react exothermically with reducing agents to release hydrogen gas. In the presence of various catalysts (such as acids) or initiators, may undergo exothermic addition polymerization reactions.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

Use caution: Liquids with this reactive group classification have been known to react with the absorbents listed below. More info about absorbents, including situations to watch out for...

  • Mineral-Based & Clay-Based Absorbents
  • Dirt/Earth

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 131 Polymerizable warning [Flammable Liquids - Toxic; polymerization hazard]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.

SPILL: Increase the immediate precautionary measure distance, in the downwind direction, as necessary.

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2020)
Firefighting
Excerpt from ERG Guide 131 Polymerizable warning [Flammable Liquids - Toxic; polymerization hazard]:

CAUTION: The majority of these products have a very low flash point. Use of water spray when fighting fire may be inefficient. CAUTION: Methanol (UN1230) will burn with an invisible flame. Use an alternate method of detection (thermal camera, broom handle, etc.).

SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam.

LARGE FIRE: Water spray, fog or alcohol-resistant foam. If it can be done safely, move undamaged containers away from the area around the fire. Dike runoff from fire control for later disposal. Avoid aiming straight or solid streams directly onto the product.

FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned master stream devices or monitor nozzles; if this is impossible, withdraw from area and let fire burn. (ERG, 2020)
Non-Fire Response
Excerpt from ERG Guide 131 Polymerizable warning [Flammable Liquids - Toxic; polymerization hazard]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors.

SMALL SPILL: Absorb with earth, sand or other non-combustible material and transfer to containers for later disposal. Use clean, non-sparking tools to collect absorbed material.

LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2020)
Protective Clothing
Goggles and face shield; protective clothing; self-contained breathing appartus for high vapor concentrations. (USCG, 1999)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
INHALATION: remove from exposure; if not breathing, give artificial respiration; if breathing is difficult, give oxygen; call physician.

EYES: flush with water for at least 15 min. and call physician.

SKIN: flush with water; get medical attention for skin irritation.

INGESTION: do NOT induce vomiting; get medical attention. (USCG, 1999)

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.

Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula:
  • C3H5Br
Flash Point: 28°F (USCG, 1999)
Lower Explosive Limit (LEL): 4.4 % (USCG, 1999)
Upper Explosive Limit (UEL): 7.3 % (USCG, 1999)
Autoignition Temperature: 563°F (USCG, 1999)
Melting Point: -182°F (USCG, 1999)
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: 1.4161 at 68°F (USCG, 1999) - Denser than water; will sink
Boiling Point: 158°F at 760 mmHg (USCG, 1999)
Molecular Weight: 121 (USCG, 1999)
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH: data unavailable

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Allyl bromide; (3-Bromopropene) (106-95-6) 0.2 ppm 12 ppm 71 ppm
(DOE, 2018)

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

No regulatory information available.

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

This section provides a listing of alternate names for this chemical, including trade names and synonyms.
  • ALLYL BROMIDE
  • BROMALLYLENE
  • 3-BROMO-1-PROPENE
  • 1-BROMO-2-PROPENE
  • 3-BROMOPROPENE
  • 3-BROMOPROPYLENE
  • PROPENE, 3-BROMO-
  • 2-PROPENYL BROMIDE

Version 3.0.0