Get the app in the App Store and on Google Play!

ETHANOL, 1,2-DICHLORO-, ACETATE

3 - Combustible liquid (U.S.)
Add to MyChemicals

The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number
  • 10140-87-1   (ETHANOL, 1,2-DICHLORO-, ACETATE)
DOT Hazard Label USCG CHRIS Code
  • Combustible Liquid
none
NIOSH Pocket Guide International Chem Safety Card
none none
NFPA 704
data unavailable
General Description
Water-white liquid. Density 1.23 g / cm3. Flash point 307°F. Low toxicity. Miscible with alcohol and ethyl ether. Insoluble in water. Used in organic synthesis.

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
none
Air & Water Reactions
Insoluble in water.
Fire Hazard
May be ignited by heat, sparks or flames. Vapors may travel to a source of ignition and flash back. Container may explode in heat of fire. Vapor explosion hazard indoors, outdoors or in sewers. Runoff to sewer may create fire or explosion hazard. When heated to decomposition, it may emit highly toxic fumes of phosgene. Esters may explode on mixing with nitrates. (EPA, 1998)
Health Hazard
This material is toxic by inhalation. (EPA, 1998)
Reactivity Profile
ETHANOL, 1,2-DICHLORO-, ACETATE is a halogenated ester. React with acids to liberate heat along with alcohols and acids. Strong oxidizing acids may cause a vigorous reaction that is sufficiently exothermic to ignite the reaction products. Heat is also generated by interaction with caustic solutions. Flammable hydrogen is generated by mixing with alkali metals and hydrides.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

No information available.

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 128 [Flammable Liquids (Water-Immiscible)]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 50 meters (150 feet) in all directions.

LARGE SPILL: Consider initial downwind evacuation for at least 300 meters (1000 feet).

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2020)
Firefighting
Move container from fire area if you can do it without risk. Cool containers that are exposed to flames with water from the side until well after fire is out. For massive fire in cargo area, use unmanned hose holder or monitor nozzles; if this is impossible, withdraw from area and let fire burn. Withdraw immediately in case of rising sound from venting safety device or any discoloration of tank due to fire. Wear self-contained (positive pressure if available) breathing apparatus and full protective clothing. Isolate one-half mile in all directions if tank car or truck is involved in fire.

To extinguish small fires: dry chemical, carbon dioxide, water spray or foam. Large fires: water spray, fog or foam. (EPA, 1998)
Non-Fire Response
Keep unnecessary people away; isolate hazard area and deny entry. Stay upwind; keep out of low areas. Shut off ignition sources; no flares, smoking or flames in hazard area. Stop leak if you can do it without risk. Use water spray to reduce vapors.

Small spills: take up with sand or other non-combustible absorbent material and place into containers for later disposal.

Large spills: dike far ahead of spill for later disposal. (EPA, 1998)
Protective Clothing
For emergency situations, wear a positive pressure, pressure-demand, full facepiece self-contained breathing apparatus (SCBA) or pressure- demand supplied air respirator with escape SCBA and a fully-encapsulating, chemical resistant suit. (EPA, 1998)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Inhalation is a route of entry.Move victim to fresh air; call emergency medical care. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. In case of contact with material, immediately flush eyes with running water for at least 15 minutes. Wash skin with soap and water. Remove and isolate contaminated clothing and shoes at the site. (EPA, 1998)

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.

Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula:
  • C4H6Cl2O2
Flash Point: 307°F (EPA, 1998)
Lower Explosive Limit (LEL): Combustible. (EPA, 1998)
Upper Explosive Limit (UEL): Combustible. (EPA, 1998)
Autoignition Temperature: data unavailable
Melting Point: Less than -26°F (EPA, 1998)
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity: 1.296 at 68°F (EPA, 1998) - Denser than water; will sink
Boiling Point: 136 to 149°F at 13 mmHg (EPA, 1998)
Molecular Weight: 157 (EPA, 1998)
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH: data unavailable

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Dichloroethanol acetate, 1,2- (10140-87-1) 0.15 ppm 1.7 ppm 10 ppm
(DOE, 2018)

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
Ethanol, 1,2-dichloro-, acetate 10140-87-1 1000 pounds 1000 pounds

(EPA List of Lists, 2022)

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

This section provides a listing of alternate names for this chemical, including trade names and synonyms.
  • 1,2-DICHLOROETHYL ACETATE
  • ETHANOL, 1,2-DICHLORO-, ACETATE

Version 3.0.0