The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number
  • 7440-41-7
DOT Hazard Label USCG CHRIS Code
  • Poison
  • Flammable Solid
NIOSH Pocket Guide International Chem Safety Card
Beryllium & beryllium compounds (as Be)external_link
NFPA 704
Diamond Hazard Value Description
1
3 0
Blue Health 3 Can cause serious or permanent injury.
Red Flammability 1 Must be preheated before ignition can occur.
Yellow Instability 0 Normally stable, even under fire conditions.
White Special
(NFPA, 2010)
General Description
A grayish-white hard light metal. Denser than water, but the powder may float. May be toxic by inhalation. Will burn if involved in a fire.

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
  • Highly Flammable
  • Strong Reducing Agent
Air & Water Reactions
Insoluble in water. Beryllium is a flammable solid that will ignite if its surroundings are on fire. It can react with water under fire conditions, but is unlikely to do so otherwise.
Fire Hazard
Special Hazards of Combustion Products: Combustion yields beryllium oxide fume, which is toxic if inhaled.

Behavior in Fire: Powder may form explosive mixture with air. (USCG, 1999)
Health Hazard
Any dramatic, unexplained weight loss should be considered as possible first indication of beryllium disease. Dust is extremely toxic when inhaled; symptoms include coughing, shortness of breath, and acute or chronic lung disease. There is no record of illness from ingestion of beryllium. Contact with dust causes conjunctival inflammation of eyes and dermatitis. (USCG, 1999)
Reactivity Profile
Boron trifluoride reacts with incandescence when heated with alkali metals or alkaline earth metals except magnesium [Merck 11th ed. 1989]. Finely divided or amalgamated metal reacts with HCl, dil HNO3, or dil H2SO4; attacked by strong base with evolution of hydrogen gas [Merck 11th ed. 1989]. It has been determined experimentally that a mixture of beryllium powder with carbon tetrachloride or with trichloroethylene will flash or spark on heavy impact [ASESB Pot. Incid. 39 1968]. The reaction between beryllium and the vapors of phosphorus proceeds with incandescence [Mellor 8:842 1946-47].
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

No information available.

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
Excerpt from ERG Guide 134 [Flammable Solids - Toxic and/or Corrosive]:

IMMEDIATE PRECAUTIONARY MEASURE: Isolate spill or leak area for at least 25 meters (75 feet) in all directions.

LARGE SPILL: Consider initial downwind evacuation for at least 100 meters (330 feet).

FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2020)
Firefighting
Excerpt from ERG Guide 134 [Flammable Solids - Toxic and/or Corrosive]:

SMALL FIRE: Dry chemical, CO2, water spray or alcohol-resistant foam.

LARGE FIRE: Water spray, fog or alcohol-resistant foam. If it can be done safely, move undamaged containers away from the area around the fire. Avoid aiming straight or solid streams directly onto the product. Do not get water inside containers. Dike runoff from fire control for later disposal.

FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned master stream devices or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. (ERG, 2020)
Non-Fire Response
Excerpt from ERG Guide 134 [Flammable Solids - Toxic and/or Corrosive]:

ELIMINATE all ignition sources (no smoking, flares, sparks or flames) from immediate area. Stop leak if you can do it without risk. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Prevent entry into waterways, sewers, basements or confined areas. Use clean, non-sparking tools to collect material and place it into loosely covered plastic containers for later disposal. (ERG, 2020)
Protective Clothing
Excerpt from NIOSH Pocket Guide for Beryllium & beryllium compounds (as Be)external link:

Skin: PREVENT SKIN CONTACT - Wear appropriate personal protective clothing to prevent skin contact.

Eyes: PREVENT EYE CONTACT - Wear appropriate eye protection to prevent eye contact.

Wash skin: DAILY - The worker should wash daily at the end of each work shift, and prior to eating, drinking, smoking, etc.

Remove: WHEN WET OR CONTAMINATED - Work clothing that becomes wet or significantly contaminated should be removed and replaced.

Change: DAILY - Workers whose clothing may have become contaminated should change into uncontaminated clothing before leaving the work premises.

Provide: EYEWASH - Eyewash fountains should be provided in areas where there is any possibility that workers could be exposed to the substances; this is irrespective of the recommendation involving the wearing of eye protection. (NIOSH, 2023)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
Excerpt from NIOSH Pocket Guide for Beryllium & beryllium compounds (as Be)external link:

Eye: IRRIGATE IMMEDIATELY - If this chemical contacts the eyes, immediately wash (irrigate) the eyes with large amounts of water, occasionally lifting the lower and upper lids. Get medical attention immediately.

Breathing: FRESH AIR - If a person breathes large amounts of this chemical, move the exposed person to fresh air at once. Other measures are usually unnecessary. (NIOSH, 2023)

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.

Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula:
  • Be
Flash Point: data unavailable
Lower Explosive Limit (LEL): data unavailable
Upper Explosive Limit (UEL): data unavailable
Autoignition Temperature: data unavailable
Melting Point: 2349°F (NIOSH, 2023)
Vapor Pressure: 0 mmHg (approx) (NIOSH, 2023)
Vapor Density (Relative to Air): data unavailable
Specific Gravity: 1.85 at 68°F (USCG, 1999) - Denser than water; will sink
Boiling Point: 4532°F at 760 mmHg (NIOSH, 2023)
Molecular Weight: 9.01 (USCG, 1999)
Water Solubility: Insoluble (NIOSH, 2023)
Ionization Energy/Potential: data unavailable
IDLH: 4 mg Be/m3 ; A potential occupational carcinogen. (NIOSH, 2023)

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

Chemical ERPG-1 ERPG-2 ERPG-3
Beryllium (7440-41-7) NA 0.025 mg/m3 0.1 mg/m3
NA = not appropriate.
(AIHA, 2022)

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Beryllium (7440-41-7) 0.0023 mg/m3 0.025 mg/m3 0.1 mg/m3
(DOE, 2018)

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

Regulatory Name CAS Number/
313 Category Code
EPCRA 302
EHS TPQ
EPCRA 304
EHS RQ
CERCLA RQ EPCRA 313
TRI
RCRA
Code
CAA 112(r)
RMP TQ
Beryllium †† 7440-41-7 10 pounds 313 P015
Beryllium Compounds N050 & 313

(EPA List of Lists, 2022)

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

This section provides a listing of alternate names for this chemical, including trade names and synonyms.
  • BERYLLIUM
  • BERYLLIUM ATOM
  • BERYLLIUM ELEMENT
  • BERYLLIUM METAL: BERYLLIUM
  • BERYLLIUM POWDER
  • BERYLLIUM, (DUST OR POWDER), METAL
  • BERYLLIUM, [POWDER]
  • BERYLLIUM-9
  • GLUCINIUM