DIETHYLENE GLYCOL MONOBUTYL ETHER ACETATE
The
Chemical Identifier fields
include common identification numbers, the
NFPA diamond
U.S. Department of Transportation hazard labels, and a general
description of the chemical. The information in CAMEO Chemicals comes
from a variety of
data sources.
CAS Number | UN/NA Number |
---|---|
|
none |
DOT Hazard Label | USCG CHRIS Code |
data unavailable | |
NIOSH Pocket Guide | International Chem Safety Card |
none |
NFPA 704
Diamond | Hazard | Value | Description | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Health | 1 | Can cause significant irritation. | |||||||||
Flammability | 1 | Must be preheated before ignition can occur. | ||||||||||
Instability | 0 | Normally stable, even under fire conditions. | ||||||||||
Special |
(NFPA, 2010)
General Description
Colorless liquid with a mild odor. Floats and mixes slowly with water. (USCG, 1999)
The
Hazard fields
include
special hazard alerts
air and water
reactions, fire hazards, health hazards, a reactivity profile, and
details about
reactive groups assignments
and
potentially incompatible absorbents.
The information in CAMEO Chemicals comes from a variety of
data sources.
Reactivity Alerts
none
Air & Water Reactions
Water soluble.
Fire Hazard
No information available.
Health Hazard
Prolonged breathing of vapor may cause irritation and nausea. Contact with liquid may cause mild irritation of eyes and skin. Can be absorbed through skin in toxic amounts. (USCG, 1999)
Reactivity Profile
Esters react with acids to liberate heat along with alcohols and acids. Strong oxidizing acids may cause a vigorous reaction that is sufficiently exothermic to ignite the reaction products. Heat is also generated by the interaction of esters with caustic solutions. Flammable hydrogen is generated by mixing esters with alkali metals and hydrides.
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents
No information available.
The
Response Recommendation fields
include isolation and evacuation distances, as well as recommendations for
firefighting, non-fire response, protective clothing, and first aid. The
information in CAMEO Chemicals comes from a variety of
data sources.
Isolation and Evacuation
No information available.
Firefighting
Fire Extinguishing Agents: Water, alcohol foam, dry chemical, carbon dioxide (USCG, 1999)
Non-Fire Response
No information available.
Protective Clothing
Face shield or safety glasses; protective gloves; air mask for prolonged exposure to vapor. (USCG, 1999)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
INHALATION: move victim to fresh air; if breathing has stopped, administer artificial respiration.
EYES: flush with water for at least 15 min.
SKIN: wash skin with large amounts of water for 15 min.; call physician if needed.
INGESTION: induce vomiting; get medical attention. (USCG, 1999)
EYES: flush with water for at least 15 min.
SKIN: wash skin with large amounts of water for 15 min.; call physician if needed.
INGESTION: induce vomiting; get medical attention. (USCG, 1999)
The
Physical Property fields
include properties such as vapor pressure and
boiling point, as well as explosive limits and
toxic exposure thresholds
The information in CAMEO Chemicals comes from a variety of
data sources.
Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula: |
|
Flash Point:
240°F
(USCG, 1999)
Lower Explosive Limit (LEL):
0.8 %
(USCG, 1999)
Upper Explosive Limit (UEL):
5 %
(USCG, 1999)
Autoignition Temperature:
563°F
(USCG, 1999)
Melting Point:
-27°F
(USCG, 1999)
Vapor Pressure: data unavailable
Vapor Density (Relative to Air): data unavailable
Specific Gravity:
0.985
at 68°F
(USCG, 1999)
- Less dense than water; will float
Boiling Point:
475°F
at 760 mmHg
(USCG, 1999)
Molecular Weight:
204.3
(USCG, 1999)
Water Solubility: data unavailable
Ionization Energy/Potential: data unavailable
IDLH: data unavailable
AEGLs (Acute Exposure Guideline Levels)
No AEGL information available.ERPGs (Emergency Response Planning Guidelines)
No ERPG information available.PACs (Protective Action Criteria)
No PAC information available.
The
Regulatory Information fields
include information from
the U.S. Environmental Protection Agency's Title III Consolidated List of
Lists,
the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility
Anti-Terrorism Standards,
and the U.S. Occupational Safety and Health Administration's
Process Safety Management of Highly Hazardous Chemicals Standard List
(see more about these
data sources).
EPA Consolidated List of Lists
No regulatory information available.CISA Chemical Facility Anti-Terrorism Standards (CFATS)
No regulatory information available.OSHA Process Safety Management (PSM) Standard List
No regulatory information available.
This section provides a listing of alternate names for this chemical,
including trade names and synonyms.
- 2-(2-BUTOXYETHOXY) ETHANOL ACETATE
- BUTYL CARBITOL ACETATE
- DIETHYLENE GLYCOL MONOBUTYL ETHER ACETATE
- DIGLYCOL MONOBUTYL ETHER ACETATE
- EKTASOLVE DB ACETATE
Contact Us | Website Satisfaction Survey
Version 3.1.0 rev 1