Get the app in the App Store and on Google Play!

PROPYLENE GLYCOL

Add to MyChemicals

The Chemical Identifier fields include common identification numbers, the NFPA diamond U.S. Department of Transportation hazard labels, and a general description of the chemical. The information in CAMEO Chemicals comes from a variety of data sources.
CAS Number UN/NA Number
  • 57-55-6
none
DOT Hazard Label USCG CHRIS Code
data unavailable
NIOSH Pocket Guide International Chem Safety Card
none
NFPA 704
Diamond Hazard Value Description
1
0 0
Blue Health 0 No hazard beyond that of ordinary combustible material.
Red Flammability 1 Must be preheated before ignition can occur.
Yellow Instability 0 Normally stable, even under fire conditions.
White Special
(NFPA, 2010)
General Description
Thick odorless colorless liquid. Mixes with water. (USCG, 1999)

The Hazard fields include special hazard alerts air and water reactions, fire hazards, health hazards, a reactivity profile, and details about reactive groups assignments and potentially incompatible absorbents. The information in CAMEO Chemicals comes from a variety of data sources.
Reactivity Alerts
none
Air & Water Reactions
Water soluble.
Fire Hazard
This chemical is combustible. (NTP, 1992)
Health Hazard
Liquid may irritate eyes. (USCG, 1999)
Reactivity Profile
PROPYLENE GLYCOL is hygroscopic. It is sensitive to excessive heat (tends to oxidize at high temperatures). This compound can react with oxidizing materials. It is incompatible with acid chlorides, acid anhydrides, chloroformates, and reducing agents. It dissolves many essential oils. A mixture of this compound with hydrofluoric acid and silver nitrate was put in a glass bottle which burst 30 minutes later. (NTP, 1992)
Belongs to the Following Reactive Group(s)
Potentially Incompatible Absorbents

Use caution: Liquids with this reactive group classification have been known to react with the absorbent listed below. More info about absorbents, including situations to watch out for...

  • Cellulose-Based Absorbents

The Response Recommendation fields include isolation and evacuation distances, as well as recommendations for firefighting, non-fire response, protective clothing, and first aid. The information in CAMEO Chemicals comes from a variety of data sources.
Isolation and Evacuation
No information available.
Firefighting
Fire Extinguishing Agents: Water fog, alcohol foam, carbon dioxide, dry chemical. (USCG, 1999)
Non-Fire Response
SMALL SPILLS AND LEAKAGE: If you should spill this chemical, use absorbent paper to pick up all liquid spill material. Seal the absorbent paper, as well as any of your clothing which may be contaminated, in a vapor-tight plastic bag for eventual disposal. Wash any surfaces you may have contaminated with a soap and water solution. Do not reenter the contaminated area until the Safety Officer (or other responsible person) has verified that the area has been properly cleaned.

STORAGE PRECAUTIONS: You should protect this material from exposure to light and moisture. Keep it away from oxidizing materials and store it under refrigerated temperatures. (NTP, 1992)
Protective Clothing
Goggles. (USCG, 1999)
DuPont Tychem® Suit Fabrics
No information available.
First Aid
EYES: First check the victim for contact lenses and remove if present. Flush victim's eyes with water or normal saline solution for 20 to 30 minutes while simultaneously calling a hospital or poison control center. Do not put any ointments, oils, or medication in the victim's eyes without specific instructions from a physician. IMMEDIATELY transport the victim after flushing eyes to a hospital even if no symptoms (such as redness or irritation) develop.

SKIN: IMMEDIATELY flood affected skin with water while removing and isolating all contaminated clothing. Gently wash all affected skin areas thoroughly with soap and water. If symptoms such as redness or irritation develop, IMMEDIATELY call a physician and be prepared to transport the victim to a hospital for treatment.

INHALATION: IMMEDIATELY leave the contaminated area; take deep breaths of fresh air. If symptoms (such as wheezing, coughing, shortness of breath, or burning in the mouth, throat, or chest) develop, call a physician and be prepared to transport the victim to a hospital. Provide proper respiratory protection to rescuers entering an unknown atmosphere. Whenever possible, Self-Contained Breathing Apparatus (SCBA) should be used; if not available, use a level of protection greater than or equal to that advised under Protective Clothing.

INGESTION: DO NOT INDUCE VOMITING. If the victim is conscious and not convulsing, give 1 or 2 glasses of water to dilute the chemical and IMMEDIATELY call a hospital or poison control center. Be prepared to transport the victim to a hospital if advised by a physician. If the victim is convulsing or unconscious, do not give anything by mouth, ensure that the victim's airway is open and lay the victim on his/her side with the head lower than the body. DO NOT INDUCE VOMITING. IMMEDIATELY transport the victim to a hospital. (NTP, 1992)

The Physical Property fields include properties such as vapor pressure and boiling point, as well as explosive limits and toxic exposure thresholds The information in CAMEO Chemicals comes from a variety of data sources.

Note: For Vapor Density and Specific Gravity, comparing the value to 1.0 can tell you if the chemical will likely sink/rise in air or sink/float in fresh water (respectively). Short phrases have been added to those values below as an aid. However, make sure to also consider the circumstances of a release. The Vapor Density comparisons are only valid when the gas escaping is at the same temperature as the surrounding air itself. If the chemical is escaping from a container where it was pressurized or refrigerated, it may first escape and behave as a heavy gas and sink in the air (even if it has a Vapor Density value less than 1). Also, the Specific Gravity comparisons are for fresh water (density 1.0 g/mL). If your spill is in salt water (density about 1.027 g/mL), you need to adjust the point of comparison. There are some chemicals that will sink in fresh water and float in salt water.
Chemical Formula:
  • C3H8O2
Flash Point: 210°F (NTP, 1992)
Lower Explosive Limit (LEL): 2.6 % (NTP, 1992)
Upper Explosive Limit (UEL): 12.6 % (NTP, 1992)
Autoignition Temperature: 700°F (USCG, 1999)
Melting Point: -76°F (NTP, 1992)
Vapor Pressure: 0.08 mmHg at 68°F ; 0.13 mmHg at 77°F (NTP, 1992)
Vapor Density (Relative to Air): 2.62 (NTP, 1992) - Heavier than air; will sink
Specific Gravity: 1.04 at 68°F (USCG, 1999) - Denser than water; will sink
Boiling Point: 370.8°F at 760 mmHg (NTP, 1992)
Molecular Weight: 76.1 (NTP, 1992)
Water Solubility: greater than or equal to 100 mg/mL at 70°F (NTP, 1992)
Ionization Energy/Potential: data unavailable
IDLH: data unavailable

AEGLs (Acute Exposure Guideline Levels)

No AEGL information available.

ERPGs (Emergency Response Planning Guidelines)

No ERPG information available.

PACs (Protective Action Criteria)

Chemical PAC-1 PAC-2 PAC-3
Propylene glycol; (1,2-Propanediol) (57-55-6) 30 mg/m3 1300 mg/m3 7900 mg/m3 LEL = 26000 ppm
(DOE, 2024)

The Regulatory Information fields include information from the U.S. Environmental Protection Agency's Title III Consolidated List of Lists, the U.S. Cybersecurity and Infrastructure Security Agency's Chemical Facility Anti-Terrorism Standards, and the U.S. Occupational Safety and Health Administration's Process Safety Management of Highly Hazardous Chemicals Standard List (see more about these data sources).

EPA Consolidated List of Lists

No regulatory information available.

CISA Chemical Facility Anti-Terrorism Standards (CFATS)

No regulatory information available.

OSHA Process Safety Management (PSM) Standard List

No regulatory information available.

This section provides a listing of alternate names for this chemical, including trade names and synonyms.
  • ALPHA-PROPYLENE GLYCOL
  • ALPHA-PROPYLENEGLYCOL
  • 1,2-DIHYDROXYPROPANE
  • DL-1,2-PROPANEDIOL
  • DL-PROPYLENE GLYCOL
  • DOWFROST
  • 2-HYDROXYPROPANOL
  • ISOPROPYLENE GLYCOL
  • METHYL GLYCOL
  • METHYLETHYL GLYCOL
  • METHYLETHYLENE GLYCOL
  • MONOPROPYLENE GLYCOL
  • PG 12
  • 1000PG
  • PROPANE-1,2-DIOL
  • (.+-.)-1,2-PROPANEDIOL
  • 1,2-PROPANEDIOL
  • 2,3-PROPANEDIOL
  • PROPYLENE GLYCOL
  • PROPYLENE GLYCOL USP
  • (.+-.)-PROPYLENE GLYCOL
  • 1,2-PROPYLENE GLYCOL
  • (RS)-1,2-PROPANEDIOL
  • 1,2-(RS)-PROPANEDIOL
  • SIRLENE
  • SOLAR WINTER BAN
  • SOLARGARD P
  • TRIMETHYL GLYCOL
  • UCAR 35

Contact Us | Website Satisfaction Surveyexternal_link